浦发彩票

Business League Customer Service

Hello, welcome to Tianjin Blower, welcome to consult ...

Mr. Mao: 点击这里给我发消息
loading

Touch screen QR code

Hello, welcome to visit Tianjin Blower Group Co., Ltd.!
13512222201 Company hotline: 13512222201
浦发彩票

Company Hotline:
13512222201

Contact:
Gross
Contact QQ:
Click me to send message
Telephone:
022-26510325
Fax:
022-26543626
Mailbox:
jgjt@vip.126.com
Address:
No. 9, Xishui West Road, Beichen District, Tianjin
Fan-Jin Blower (Online Consultation) -Anhui Fan

Fan-Jin Blower (Online Consultation) -Anhui Fan

Tianjin Blower Group Co., Ltd.
  • Business model: production and processing
  • Address: No. 9 Xishui West Road, Beichen District, Tianjin
  • Main: Fans, Blower Fans, Centrifugal Fans
Business Hotline: 13512222201
  • Product Details
  • contact details
      Fan-Jin Blower (Online Consultation) -Anhui Fan:
      Tianjin fan , Tianjin blower , Tianjin fan
      Enterprise video show broadcast, please click to play
      Video by: Jin Blower Works Group Co., Ltd.





      After the centrifugal fan is assembled, it needs to be spray-painted, mainly to improve its cleanliness and improve its anticorrosive performance. Therefore, once the spray painting effect is not good, the Hubei ventilator will have a certain impact on the fan, such as shortening its service life, easy to be corroded, and speeding up the damage of various parts. Therefore, when spray painting, special attention must be paid to avoid poor paint quality.

      1. Before spraying the centrifugal fan, it must be handled in place, which specifically involves degreasing and decontamination. At the same time, it is necessary to confirm that the welding and the surface of the parts are smooth. No appearance defects are allowed. Good surface packaging.

      2. Of course, the cleanliness of the environment is also important for the paint quality of the fan. Therefore, the dust on the ground and surrounding objects must be cleaned; the pressure of the air pump should be adjusted to not less than 4MPa, and the spraying device and objects should not exceed 30cm.

      3. The paint used for centrifugal fan spraying must be matched according to a certain proportion in advance. The Jiangxi ventilator basically guarantees that the viscosity of the paint meets the technical requirements and that there are no quality defects such as leaking spray, bubbles, orange peel, etc. after spray painting is completed. After the fan finishes the rust-proof paint twice and finishes the paint twice, it is ensured that the appearance of the fan is bright, smooth, and has good adhesion, which meets the technical requirements.

      4. Due to the hidden safety hazards in the production process of the motor wheels, V-belts and other moving parts of the centrifugal fan, it should be sprayed with eye-catching paint. The dried or naturally dried machine is riveted with a label and a product nameplate to ensure that the riveting is firm, not subject to vibration and deformation, and consistent with the product.

      Therefore, a centrifugal fan can run normally, and it can not be used for a long time without problems in all aspects, such as painting, installation, operation, and post-maintenance. Long-lasting, stable, and safe to use.




      Tianjin Blower Group Co., Ltd. is a professional manufacturer of various fan designs and manufacturers. The company has senior engineering and technical personnel, advanced processing equipment, production technology and perfect detection methods and management systems, fans, strong technical force and stable product quality. Passed ISO9001: 2008 international quality management system certification.


      [Must-see]-Tips for installing fire exhaust fan:

      <1> Pay attention to maintain the horizontal position of the fan when installing the fire smoke exhaust fan. The connection between the fan and the foundation and the connection of the air outlet pipe should be adjusted so that it matches naturally. There must be no forced connection. It is not allowed to add pipe weight to the fan. On the parts.

      <2> When installing the fan, check all parts, whether the parts are complete and whether the parts are tightly connected.

      <3> If abnormal phenomena such as severe vibration and shock are found during operation of the fire exhaust fan, the machine must be stopped and inspected immediately.

      <4> The fan should be protected against rain in the open air.

      <5> Remove dust, dirt and other impurities inside the fan on schedule and prevent rust.




      Use classification of fan:

      Fans can also be divided into multiple types according to different purposes, such as smoke exhaust fans, air conditioning fans, roof fans and so on. These fans are designed for special purposes, so they are different from ordinary fans in terms of shape, material and function. For example, roof fans can be designed to be bidirectional reversible air supply and exhaust.

      Other classifications of fans;

      According to the different number of air blowers, the fans can be single-stage, double-stage and multi-stage fans. For example, Roots fans are typical multi-stage fans. According to the structure of the design and the installation position of the motor, the fan can also be a type of fan-in fan and draw-out fan.



      Jin Blower Group (picture) -Jiangxi Fan-Ventilator is provided by Jin Blower Group Co., Ltd. Tianjin Blower Group Co., Ltd. (fuzzlinks.com) is a company engaged in "fan blower centrifugal fans". Since its inception, we have adhered to the principle of "honesty, stable operation", and have been brave enough to participate in healthy competition in the market, so that the "Jin Blowers" brand has a good reputation. We adhere to the "service first, customer first" principle, so that Jin Blower has won the trust of customers in fans and exhaust equipment, and has established a good corporate image. Special note: The pictures and information in this information are for reference only. Welcome to 浦发彩票 for accurate information. Thank you!

    津鼓风机集团有限责任公司 版权所有 Copyright © 2019 Jin Blower Group Co., Ltd. All rights reserved

    电话:022-26510325 传真:022-26543626 Contact: Mr. Mao 13512222201 Phone: 022-26510325 Fax: 022-26543626

    网站备案号: 津ICP备19001615号-1 Address: No. 9 Xishui West Road, Beichen District , Tianjin

    Main Products: Tianjin Fan, Tianjin Blower, Tianjin Fan

    Sitemap

    Information detection Business League Certification Report Center Alarm service