浦发彩票

Business League Customer Service

Hello, welcome to Tianjin Blower, welcome to consult ...

Mr. Mao: 点击这里给我发消息
loading

Touch screen QR code

Hello, welcome to visit Tianjin Blower Group Co., Ltd.!
13512222201 Company hotline: 13512222201
浦发彩票

Company Hotline:
13512222201

Contact:
Gross
Contact QQ:
Click me to send message
Telephone:
022-26510325
Fax:
022-26543626
Mailbox:
jgjt@vip.126.com
Address:
No. 9, Xishui West Road, Beichen District, Tianjin
Roots Fan-Jin Blower (Recommended Business) -Hunan Roots Fan

Roots Fan-Jin Blower (Recommended Business) -Hunan Roots Fan

Tianjin Blower Group Co., Ltd.
  • Business model: production and processing
  • Address: No. 9 Xishui West Road, Beichen District, Tianjin
  • Main: Fans, Blower Fans, Centrifugal Fans
Business Hotline: 13512222201
  • Product Details
  • contact details
      Roots Fan-Jin Blower (Recommended Business) -Hunan Roots Fan:
      Tianjin fan , Tianjin blower , Tianjin fan
      Enterprise video show broadcast, please click to play
      Video by: Jin Blower Works Group Co., Ltd.





      If the rotary fan fails, please check it carefully to determine the cause of the failure, and then repair it. Roots fans, the replacement parts need to be purchased according to the original fan accessory model.

      1.Dismantling methods of rotary fan host

      a. Remove the belt cover and belt.

      b. Loosen the fixing bolt of the end cover on the side of the fan cover.

      c. Screw in the two threaded holes in the end cover and remove the end cover.

      d. Remove the V-belt from the shaft.

      e. Loosen the fixing bolt of the end cover on the side of the V-belt pulley and remove the end cover. Note: When disassembling the main unit, be careful not to hit the parts. The Yunnan Roots blower should be carefully placed.

      2. Repair of the rotary fan host

      After disassembling the main unit, use fine sandpaper or whetstone to grind the parts where the rotor, cylinder block, end cover, blades, rings and other parts are damaged or rusted, and wash them carefully with cleaning oil (be careful not to hurt the parts). reassemble. Initial burnout, mixed debris, moisture and other failures can be repaired by the above methods. When the bearings, oil seals, etc. are damaged, they need to be replaced. Be sure to replace the O-ring.

      3.Assembling methods of rotary fan host

      a. Place the end cap with the shaft hole on the assembly table.

      b. Put the side of the pulley of the rotor shaft down on the end cover.

      c. Install the spring pin into the rotor shaft.

      d. Install the blade into the rotor slot.

      e. Put on the cylinder block (note that the position of the air outlet is on the side of the rotor near the hole in the cylinder block).

      f. Insert the branch ring.

      g. Install the bearing.

      h. Install the O-ring.

      i. Install the other end cover and fix the bolt.

      j. Turn the cylinder block over and take off the end cap on the side of the pulley.

      k. Put the branch ring.

      l Install the bearing and O-ring. m. Install oil seal on the end cap.

      n. Install the end cover, place the positioning pins, and tighten all the bolts.

      o. Stand up the main machine, put the positioning pin on the other end cover, Sichuan Roots Fan, and tighten all the bolts.

      p. Pour a small amount of lubricating oil into the air inlet to fix the pulley on the rotating shaft. While turning the pulley by hand, lightly tap the end cover rib with a wooden or rubber hammer to allow the rotor shaft to move flexibly.




      Technical requirements for fire exhaust fan

      Product performance requirements,

      1. The motor adopts high-quality motor.

      2. The fire exhaust fan should be able to run normally for a long time under the condition that the medium temperature is not higher than 85 ℃.

      3. The fire exhaust fan should ensure that it can work continuously for 30min when the temperature of the conveying medium is 280 ℃, and it can continue to operate normally when the temperature of the medium is cooled to the ambient temperature

      4. At the rated speed, in the working area, the measured pressure curve of the fan and the curve given in the manual should meet the following requirements:

      a) At the specified flow rate, the axial pressure fire smoke exhaust fan has a deviation of ± 5%.

      b) At the specified flow rate, the corresponding pressure difference of the centrifugal smoke exhaust fan is ± 5%.

      5. The noise limit of sound level A of fire exhaust ventilator at the given operating point in the description shall comply with the provisions of JB / T8690.


      Jin Blower Group teaches you how to choose the right fan:

      The correct selection of the ventilator is an important step to ensure the normal and economical operation of the ventilation system. The selection principle of the fan: first, high applicability; second, strong reliability; third, good economy.

      High applicability, which means that the use, structure, and performance parameters of the selected fan meet the conditions and requirements of the working conditions. For example, fire exhaust fans used under high temperature, high pressure, and smoke conditions have special requirements for the materials of the fans. If you do n’t have the type and number of the fan you need, you ca n’t overcharge it, you should ask the fan manufacturer to design another.


      Reliability means that the design and manufacturing quality of the selected fan fully meets the relevant national technical standards, and the quality of the accessories (such as the motor (or steam turbine) and bearings) matching the fan meets the relevant national technical standards. The fan operates reliably and has a long service life.

      The economy is good, which means that the fan has high efficiency, low energy consumption, low noise, and small size. Fujian Roots fan has less space, low cost, and convenient maintenance and repair.



      Roots Fan-Fujian Roots Fan-Jin Blower (Recommended Business) is provided by Jin Blower Group Co., Ltd. Tianjin Blower Group Co., Ltd. (fuzzlinks.com) is a company engaged in "fan blower centrifugal fans". Since its inception, we have adhered to the principle of "honesty, stable operation", and have been brave enough to participate in healthy competition in the market, so that the "Jin Blowers" brand has a good reputation. We adhere to the "service first, customer first" principle, so that Jin Blower has won the trust of customers in fans and exhaust equipment, and has established a good corporate image. Special note: The pictures and information in this information are for reference only. Welcome to 浦发彩票 for accurate information. Thank you!

    津鼓风机集团有限责任公司 版权所有 Copyright © 2019 Jin Blower Group Co., Ltd. All rights reserved

    电话:022-26510325 传真:022-26543626 Contact: Mr. Mao 13512222201 Phone: 022-26510325 Fax: 022-26543626

    网站备案号: 津ICP备19001615号-1 Address: No. 9 Xishui West Road, Beichen District , Tianjin

    Main Products: Tianjin Fan, Tianjin Blower, Tianjin Fan

    Sitemap

    Information detection Business League Certification Report Center Alarm service