浦发彩票

Business League Customer Service

Hello, welcome to Tianjin Blower, welcome to consult ...

Mr. Mao: 点击这里给我发消息
loading

Touch screen QR code

Hello, welcome to visit Tianjin Blower Group Co., Ltd.!
13512222201 Company hotline: 13512222201
浦发彩票

Company Hotline:
13512222201

Contact:
Gross
Contact QQ:
Click me to send message
Telephone:
022-26510325
Fax:
022-26543626
Mailbox:
jgjt@vip.126.com
Address:
No. 9, Xishui West Road, Beichen District, Tianjin
Jin blower (Figure) | Ventilator which is good | Ventilator

Jin blower (Figure) | Ventilator which is good | Ventilator

Tianjin Blower Group Co., Ltd.
  • Business model: production and processing
  • Address: No. 9 Xishui West Road, Beichen District, Tianjin
  • Main: Fans, Blower Fans, Centrifugal Fans
Business Hotline: 13512222201
  • Product Details
  • contact details
    • Product Brand: Tianjin Blower
    • Total Supply: Unlimited
    • Price Description: Negotiated
    • Packing instructions: unlimited
    • Logistics Description: Freight and Logistics
    • Delivery instructions: by order
    • Valid until: long-term validity
    Jin Blower (Picture) | Ventilator Which is Good | Ventilator:
    Tianjin fan , Tianjin blower , Tianjin fan

    Quick repair of high temperature fan impeller

    Fast repair of cement high-temperature fan impeller An Guangxi, Yang Weichen (Lunan Cement Co., Ltd., Tengzhou, Shandong 277531) produced 2300t / d), put into production in 1990 and 1991 respectively. Two high-temperature fans have been running smoothly and the impeller has Overhauled and replaced. During the routine inspection in June 2004, it was found that the blade of No. 2 fan impeller wears out a large gap. When it runs to September, the fan has a large vibration, and it often reports alarms, trips, fans, and stops. It is found that the blade wear is serious. It is too bad to continue to run. Therefore, it was decided to carry out emergency repair without disassembling the impeller on site. It only took more than 60 hours from shutdown to resume operation, reducing accident losses.

    1 Brief introduction of high temperature fan 1600-6; Rated speed 995r / min; Rated power 1600kW; Hydraulic coupler model YOTC-1000; Output power 610 ~ 1800kW. 2 Construction preparation (determined by the size of the original fan blade); J557 welding electrode 20kg; 3 bottles of oxygen;

    One angle grinder and one portable vibration measuring instrument (set); six dynamic balance test blocks.

    3 Construction method Cut the maintenance square hole directly on the casing without dismantling the casing, which can allow one person to sit on the casing and contact the impeller for maintenance operations to speed up the construction. After the construction is completed, it will be restored as it is.

    According to the on-site impeller wear, draw a cutting line on the blade, and cut off all the thinned and worn parts of the blade. Use an angle grinder to polish the surroundings of the incision to remove debris such as welding slag and burrs to facilitate the next welding work.

    Cut the blade spare parts according to the size of the cut blade. The three sides of the spare steel plate contacting the impeller shall be ground to a single-sided groove.

    Welding adopts cold welding method and DC reverse connection. Master well during welding. Pay attention to fill the arc pit when the electrode is closed. Use an angle grinder on the back to carefully remove the roots. After confirming that there are no defects, repeat the above steps to weld the back. After welding, the skin must be carefully removed and must be removed.

    The personnel left the inspection square hole and started the motor after confirming the safety.

    The hydraulic coupler slowly adjusts the impeller speed from low to high, and uses a vibrometer to measure the horizontal and vertical vibration values of the two bearing blocks, respectively. The rotation speed is stable for 30 minutes at 200, 400, 600, 800, 900, and 950 r / min, and the bearing vibration value and temperature rise are recorded.

    During the speed-up operation, if the vibration value exceeds the limit, the speed-up should be stopped immediately, the price of the fan should be stable, and the vibration value and vibration direction should be measured to determine the positioning position of the balance weight.

    The above steps need to be repeated until each vibration value is within the standard allowable range. Finally, the vibration value of No. 2 high-temperature fan is: at the impeller speed of 930r / min, the horizontal vibration of the transmission side bearing is 1.2mm / s, and the vertical vibration is 0.8mm / s; the horizontal vibration of the non-drive side bearing is 1.1mm / s, and the vertical vibration is 0.8mm / s, in full compliance.

    The square hole was restored for maintenance, and the rotary kiln was ignited and put into production smoothly. The production of high and high temperature fans runs smoothly. The online vibration meter shows that when the rotary kiln feeds 152t / h and the impeller speed is 845r / min, the horizontal vibration of the transmission side bearing is 100 | JLm, the vertical vibration is 50 | xm; the horizontal vibration of the non-drive side bearing is 90 | xm, vertical vibration 46 | xm, fully meets production needs.

    4 Attentions During maintenance, the scribe cutting of the impeller blade, grinding of the impeller notch, preparation of blade spare parts, and welding of the blade are completed by one person to ensure the uniformity of the processing volume. If it can't be done by one person, at least one process should be done by one person.

    The impeller must be carefully cleaned up before the dynamic balance of the impeller, including the crusts, ash deposits, welding slag, and chemical skin on the impeller, etc., to ensure the authenticity of the dynamic balance. this point is very important.

    If conditions permit, the dynamic balance test shall be performed with an on-site dynamic balance instrument. This saves time and improves accuracy.

    The fan has been running smoothly after repair, and the operating rate is above 95%.

    During the planned inspection in January 2005, it was found that the weld seams were still clearly visible, almost no wear was observed, and it was determined that they could run for a long time. From this point of view, this method can be used for both emergency repairs and regular planned maintenance to reduce maintenance costs, which fan is better , and shorten maintenance time.

    Welding speed, can fill the weld seam once, try to make the welding material fill evenly b


    Fans are widely used in textile enterprises, not only for ventilation and dust extraction of textile air conditioning and dust removal systems, but also for various textile process hosts for suction negative pressure and impurity removal.

    At present, the textile fan widely used in China is mainly made by introducing and digesting foreign advanced equipment in the 1990s. In recent years, the cooperation between domestic fan enterprises and colleges and universities has developed and improved textile axial fans, spray fans, air spinning fans, compact spinning fans, and cotton spinning fans, making the performance and quality of the main varieties of textile fans Has been further improved. In the future, textile fans will continue to develop in terms of high efficiency, low noise, combination, automation, serialization, generalization, standardization, and good safety and reliability.


    The price of fan, Tianjin blower and fan is provided by Tianjin Blower Group Co., Ltd. "Fan blower fan ventilator centrifugal fan" was selected Jin Blower Group Co., Ltd. (fuzzlinks.com), the company is located in: 109, Jiping Dongli, Hongqiao District. Customers provide excellent service, contact person: Mr. Mao. Welcome new and old customers to call us, email us, visit us and negotiate business. Jin Blower looks forward to becoming your long-term partner!

津鼓风机集团有限责任公司 版权所有 Copyright © 2019 Jin Blower Group Co., Ltd. All rights reserved

电话:022-26510325 传真:022-26543626 Contact: Mr. Mao 13512222201 Phone: 022-26510325 Fax: 022-26543626

网站备案号: 津ICP备19001615号-1 Address: No. 9 Xishui West Road, Beichen District , Tianjin

Main Products: Tianjin Fan, Tianjin Blower, Tianjin Fan

Sitemap

Information detection Business League Certification Report Center Alarm service