浦发彩票

Business League Customer Service

Hello, welcome to Tianjin Blower, welcome to consult ...

Mr. Mao: 点击这里给我发消息
loading

Touch screen QR code

Hello, welcome to visit Tianjin Blower Group Co., Ltd.!
13512222201 Company hotline: 13512222201
浦发彩票

Company Hotline:
13512222201

Contact:
Gross
Contact QQ:
Click me to send message
Telephone:
022-26510325
Fax:
022-26543626
Mailbox:
jgjt@vip.126.com
Address:
No. 9, Xishui West Road, Beichen District, Tianjin
Blower_Jin Blower (Quality Merchant) _ Which Blower Manufacturer Is Good

Blower_Jin Blower (Quality Merchant) _ Which Blower Manufacturer Is Good

Tianjin Blower Group Co., Ltd.
  • Business model: production and processing
  • Address: No. 9 Xishui West Road, Beichen District, Tianjin
  • Main: Fans, Blower Fans, Centrifugal Fans
Business Hotline: 13512222201
  • Product Details
  • contact details
    • Product Brand: Tianjin Blower
    • Total Supply: Unlimited
    • Price Description: Negotiated
    • Packing instructions: unlimited
    • Logistics Description: Freight and Logistics
    • Delivery instructions: by order
    • Valid until: long-term validity
    Blower_Jin Blower (Quality Business) _Which Blower Manufacturer Is Good:
    Tianjin fan , Tianjin blower , Tianjin fan

    How centrifugal blowers work

    The working principle of a centrifugal blower is similar to a centrifugal fan, except that the compression process of air is usually carried out under the action of centrifugal force through several working impellers (or several stages). The blower has a rotor that rotates at a high speed. The blades on the rotor drive the air at high speed. The centrifugal force causes the air to flow in the involute-shaped casing along the involute to the fan outlet. The new air is replenished from the center of the case.

    The working principle of the single-stage high-speed centrifugal fan is: the prime mover rotates the impeller through the shaft at high speed. The airflow enters the high-speed rotating impeller from the axial direction of the inlet and becomes radial flow and is accelerated. Then it enters the expansion chamber, changes the flow direction and decelerates. This deceleration converts the kinetic energy in the high-speed rotating airflow into pressure energy (potential energy), so that the fan outlet maintains a stable pressure.

    In theory, the pressure-flow characteristic curve of a centrifugal blower is a straight line. However, due to the frictional resistance and other losses inside the fan, the actual pressure and flow characteristic curve gradually decreases with the increase of the flow. The power of the corresponding centrifugal fan- The flow curve increases with increasing flow. When the fan is running at a constant speed, the operating point of the fan will move along the pressure-flow characteristic curve. The operating point of the fan during operation depends not only on its own performance, but also on the characteristics of the system. When the resistance of the network increases, the performance curve of the pipeline will become steeper. The basic principle of fan regulation is to obtain the required working conditions by changing the performance curve of the fan itself or the characteristic curve of the external pipe network.



    Wear and treatment of tunnel fan impellers

    Wear of impeller

    After the fan impeller rotates, a small amount of large particles and many tiny dust particles can be passed through the induced fan along with high temperature and high speed smoke. In the long run, blade-like wear is formed at the blade exit. Because this wear is irregular, it causes imbalance in the impeller. In addition, the impeller surface is easily oxidized at high temperatures, and the blower generates thick oxide scale. The binding force of these oxide scales to the surface of the impeller is not uniform, and some oxide scales will fall off automatically under the action of vibration or centrifugal force, which is also a cause of the imbalance of the impeller.

    2. Fouling of the impeller

    The humidity of the flue gas in the tunnel construction tunnel is very high. Although the dust particles that have not been cleaned are small, they have a high viscosity. When they pass through the induced wind, they will be adsorbed on the non-working surface of the blade under the action of the gas vortex, especially at the inlet and outlet of the non-working surface, which will form more serious dust fouling, and gradually thicken. When part of the dust falls off under the combined effect of centrifugal force and vibration, the balance of the Tianjin blower and impeller is destroyed, and the entire induced fan will vibrate.

    2, countermeasures to resolve the imbalance of the impeller:

    1. In addition to improving the ventilation effect of the fan , the best way to solve the impeller wear is to improve the anti-wear ability of the impeller.

    At present, the more mature method in this regard is that the impeller is precision-casted, added with anti-wear metal elements, and then subjected to thermal spraying technology, that is, special methods to change the wear-resistant and high-temperature resistant metal or ceramic materials The high-speed particle flow is sprayed onto the surface of the impeller blades to form a layer of tough outerwear that is much more resistant to abrasion, high temperature and oxidation than the materials of the impeller itself. This can not only reduce the damage caused by the impeller's dynamic balance, but also reduce the imbalance caused by the oxide layer.



    Blower, Tianjin Blower Price , Jin Blower (Quality Merchant) are provided by Jin Blower Group Co., Ltd. Tianjin Blower Group Co., Ltd. (fuzzlinks.com) provides customers with "fan blower centrifugal fans" and other businesses. The company has brands such as "Jin Blower". Focusing on fans, exhaust equipment and other industries, it has a high reputation in Tianjin and Tianjin. For more information, please contact: Mao Bingquan.

津鼓风机集团有限责任公司 版权所有 Copyright © 2019 Jin Blower Group Co., Ltd. All rights reserved

电话:022-26510325 传真:022-26543626 Contact: Mr. Mao 13512222201 Phone: 022-26510325 Fax: 022-26543626

网站备案号: 津ICP备19001615号-1 Address: No. 9 Xishui West Road, Beichen District , Tianjin

Main Products: Tianjin Fan, Tianjin Blower, Tianjin Fan

Sitemap

Information detection Business League Certification Report Center Alarm service